buchi rotavapor r-100 manual
Digital display of set and actual temperature (alternating). sudden cooling, too little heat flow, etc.) Product names and registered or unregistered trademarks that are used in this instruc tion manual are used only for identification and remain the property of the owner in each case. Description Order no. 10 | Appendix BCHI Labortechnik AG Water regulation nozzle. 20mL zyl. Find chromatography systems and accessories for every step of your workflow, from flash to prep HPLC. BUCHI reserves the right to make changes to the manual as deemed necessary in the light of experi ence especially in respect to structure, illustrations and technical detail. #rotaryevaporator #evaporatorFollow this detailed step-by-step video of Rotavapor R-100 and Vacuum Pump V-100 installation. Upload manuals that we do not have and get, 3.5.2 Protection against electrical overload, 5.5 Connecting the vacuum and cooling media tubing, 5.8 Setting up and filling the heating bath, 6.1.3 Adjusting immersion angle of evaporating flask, 6.1.5.1 Moving the vertical adjustment range up/down, 6.2.1 Raising and lowering the evaporating flask, 6.2.4 Feeding solvent during distillation, 7.1 Inspecting and cleaning the vapor duct. u NOTICE! BUCHI ROTAVAPOR R-220 OPERATION MANUAL Pdf Download The Rotavapor R-100 meets all of your essential needs in evaporation. The device carries the following warning symbol: 617 x 898 x 502 mm (inc. condenser and heating, 480 x 626 x 502 mm (w/o condenser and heating, 19 kg (depending on glassware included). It can be used in laboratories and production facilities for the following operations: Evaporating and condensing solvents and suspensions Synthesis and purification of refined chemicals Recycling and concentration of solvents Recrystallization Drying of powders and granulates 2. They have to be regularly inspected, cleaned and, if necessary, replaced. uTechnical modifications to the device or accessories should only be carried out with the prior written approval of BCHI Labortechnik AG and only by authorized BUCHI technicians. Avantor helps keep you safe with a robust line of safety products and personal protective equipment -- from waste bins to safety signs. As your trusted, collaborative partner, Avantor Services helps you increase efficiency, maximize productivity, and accelerate innovation. For written guidance, check the . The operator (generally the laboratory manager) is responsible for the following as. The laboratory spray dryer combines outstanding product design with unique instrument capabilities to offer a superior user experience. Imprint Product Identification: Operation Manual (Original) Rotavapor R100 11593663 en Publication date: 12.2014, Version B BCHI Labortechnik AG Meierseggstrasse 40 Postfach CH9230 Flawil 1 EMail: quality@buchi.com BUCHI reserves the right to make changes to the manual as deemed necessary in the light of experi ence; especially in respect . Buchi Rotavapor R-100 Rotary Evaporators 11100C101 - Wolflabs 2 | Safety BCHI Labortechnik AG u Always wear appropriate personal protective equipment such as safety goggles, protective clothing and gloves. Operation Manual (Original) Rotavapor R-100 11593663 Publication date: 10.2019 BCHI Labortechnik AG Meierseggstrasse 40 Postfach CH-9230 Flawil 1 E-Mail: quality@buchi.com BUCHI reserves the right to make changes to the manual as deemed necessary in the light of experi-ence, especially with respect to structure, illustrations and technical . u Wear work overalls or protective clothing. To fasten condenser 032013 Cross sleeve. Thanks to smart system design and substantial reductions in organic solvent use, the Sepiatec SFC line enables a more efficient and eco-friendly purification performance. The F100 and F105 are sealedsystem recirculating chillers. (60 pages) Laboratory Equipment Buchi Rotavapor R-3000 Operating Instructions Manual. The products you use, the products you need, the suppliers you trust for chromatography. These operating instructions apply to all variants of the Rotavapor R100 and are in tended primarily for laboratory staff. The independent heating bath is controlled by an integrated digital display and can easily be operated separately for different applications. u Do not wear loose or baggy items of clothing such as scarves or neckties. Turn off the rotary drive unit (set the rotation speed to 0 rpm). any latin characters (a-z, A-Z) any numbers (0-9) special characters ("-", "_" and ". u Use only genuine BUCHI accessories, spare parts and consumables. Follow the links below for an up-to-date list of spare parts and service availability for legacy devices from BUCHI technical support. Insert seal (2) into the flange of the condenser (1) as shown. Rotavapor R-100. Shop By. u Always visually inspect glass components for damage every time they are to be used. There are four danger levels, each identifiable by the signal word used. Fisher Scientific is always working to improve our content for you. Using a narrow object or screwdriver, press the switch (1) on the underside of the heating bath. Rotavapor R-100 Rotary Evaporators Standalone, BUCHI, Life Science Research Solutions, Products, and Resources, Controlled Environment and Cleanroom Solutions, How to Select the Right Chromatography Resin, Thermo Scientific Chromatography Columns and Consumables, Liquid Chromatography - Sample Preparation, Biopharma production chemicals & excipients, Laboratory Personal Protection Equipment (PPE) and Workwear Products, Laboratory Facilities Maintenance, Protection, and Hygiene Supplies, Building a Safe Work Environment with VWR, New Solutions - Controlled Environment and Cleanroom Products, Solutions by Industry Controlled Environment and Cleanroom Product, Safety and Controlled Environment Featured Brands, Controlled Environment & Cleanroom Sustainable Solutions, Masterflex Peristaltic Pump and Fluid Handling Solutions, Quality Products from Sheldon Manufacturing, Lab Thermometers & Temperature Measurement Equipment, Agilent Chemistries and Supplies Portfolio, PerkinElmer - Innovating for a Healthier World, Sartorius laboratory instruments, consumables and services, HALO Chromatography Columns and Consumables+-, The Avantor Value as a Medical Lab Partner, Reference materials Laboratory Products, Specialized Solutions for Cutting Applications, Contact Your Laboratory Furniture Specialist. This manual is copyrighted. It has always been our goal at BUCHI to develop long-lasting and reliable instruments. 1 2 3 4 5 1 Vacuum connection seal 4 Feed tubing seal 2 Coolant seal 5 Vacuum gasket (not visible) 3 Coolant seal u Remove seals and inspect for damage and cracks. u If pure distilled or deionised water has to be used, add 1 to 2 g of Borax (Na2B4O7 x 10 H2O) per litre of water. Distillation can produce dangerous vapors that are capable of causing lifethreatening toxic effects. BCHI Labortechnik AG Help with faults | 8 Fault Possible cause Optimum distilla Too much backevaporation tion not from the receiving flask (espe achieved cially with solvent mixtures) Other faults in distillation process (e.g. The vapor duct snaps into place with an audible click. 5. Our global footprint enables us to serve more than 300,000 customer locations and gives us extensive access to research laboratories and scientists in more than 180 countries. Want your creations to burst with flavor? The R-300 meets the highest expectations in convenience and versatility. u Make sure that any dripping condensate cannot cause any damage. Restriction valve, hose clamp, sieve Used when tap water is applied as vacuum source, to reduce flowrate of the water 011606 Water jet pump. The compact system can be operated anywhere by anyone thanks to a simple interface and pre-calibration packages that ensure speed and quality. BUCHI reserves the right to make changes to the manual as deemed necessary in the light of experi ence; especially in . Quick and ergonomic operation with smooth manual lift mechanism; Easy flask handling and vapor duct removal due to multifunctional Combi-Clip; u Switch off the device. Couppling, pressure spring 048237 Rubber band. As our customers needs have evolved, so have our capabilities. High-quality chemicals and services, customized to your product or manufacturing needs VWR enables the advancement of science by providing high-quality chemicals and services, customized to your product or manufacturing needs. particularly suitable for the Rotavapor R-100. The Rotavapor R-100 is an effective rotary evaporator for limited budgets. (60 pages) Laboratory Equipment Buchi Rotavapor R-100 Operation Manual. If vapors escape from joints or connections, check the seals concerned and re place them if necessary. 100mL flask (5pcs) 001333 Glass, SJ29/32, incl. 50mL flask (5pcs) 011574 Glass, SJ29/32, incl. The glass stopcock performs various functions depending on its position: Glass stopcock handle pointing forwards or backwards: the system is sealed. New Avantor J.T.Baker premium conductive and non-conductive robotic tips deliver superior quality and reliable performance for results you can trust. to BUCHI products Status Color explanation Spare parts and service available . Add to Wish List Add to Compare. "), Operation Manual (Original) Rotavapor R100 11593663 en. Its modular design allows extension of the Rotavapor R-300 to a fully integrated system where a central interface regulates each component. Don't miss out, order yours today! 5 | Installation BCHI Labortechnik AG 5.8 Setting up and filling the heating bath 1 2 u Locate the heating bath (1) in the Lshaped cutout in the Rotavapor base (2). Buchi Rotavapor R-100 Operation Manual (60 pages) Brand: Buchi | Category: Laboratory Equipment | Size: 4.35 MB Table of Contents. 2.6 Modifications Unauthorized modifications may impair safety and lead to accidents. u If a vacuum pump is not used, leave the vacuum connection open. 10 | Appendix BCHI Labortechnik AG Cap nuts, set. Rotary evaporator Buchi Rotavapor R-100 system vertical condenser, for use under vacuum, manual flask lift, safety coating on glassware, F-105 chiller included, V-100 pump and I-100 pump controller included, B-100 bath included Power Draw: 2.74kW: Ecological Features: In continuous uncontrolled operations, drops power consumption automatically. Ibanez Steve Vai Signature Jem Series, Georgia State University Grades, Bosch Gws10 8 76v Ec Professional Compact Angle Grinders, Voigtlander Bessa Eyepiece, Articles B
Digital display of set and actual temperature (alternating). sudden cooling, too little heat flow, etc.) Product names and registered or unregistered trademarks that are used in this instruc tion manual are used only for identification and remain the property of the owner in each case. Description Order no. 10 | Appendix BCHI Labortechnik AG Water regulation nozzle. 20mL zyl. Find chromatography systems and accessories for every step of your workflow, from flash to prep HPLC. BUCHI reserves the right to make changes to the manual as deemed necessary in the light of experi ence especially in respect to structure, illustrations and technical detail. #rotaryevaporator #evaporatorFollow this detailed step-by-step video of Rotavapor R-100 and Vacuum Pump V-100 installation. Upload manuals that we do not have and get, 3.5.2 Protection against electrical overload, 5.5 Connecting the vacuum and cooling media tubing, 5.8 Setting up and filling the heating bath, 6.1.3 Adjusting immersion angle of evaporating flask, 6.1.5.1 Moving the vertical adjustment range up/down, 6.2.1 Raising and lowering the evaporating flask, 6.2.4 Feeding solvent during distillation, 7.1 Inspecting and cleaning the vapor duct. u NOTICE! BUCHI ROTAVAPOR R-220 OPERATION MANUAL Pdf Download The Rotavapor R-100 meets all of your essential needs in evaporation. The device carries the following warning symbol: 617 x 898 x 502 mm (inc. condenser and heating, 480 x 626 x 502 mm (w/o condenser and heating, 19 kg (depending on glassware included). It can be used in laboratories and production facilities for the following operations: Evaporating and condensing solvents and suspensions Synthesis and purification of refined chemicals Recycling and concentration of solvents Recrystallization Drying of powders and granulates 2. They have to be regularly inspected, cleaned and, if necessary, replaced. uTechnical modifications to the device or accessories should only be carried out with the prior written approval of BCHI Labortechnik AG and only by authorized BUCHI technicians. Avantor helps keep you safe with a robust line of safety products and personal protective equipment -- from waste bins to safety signs. As your trusted, collaborative partner, Avantor Services helps you increase efficiency, maximize productivity, and accelerate innovation. For written guidance, check the . The operator (generally the laboratory manager) is responsible for the following as. The laboratory spray dryer combines outstanding product design with unique instrument capabilities to offer a superior user experience. Imprint Product Identification: Operation Manual (Original) Rotavapor R100 11593663 en Publication date: 12.2014, Version B BCHI Labortechnik AG Meierseggstrasse 40 Postfach CH9230 Flawil 1 EMail: quality@buchi.com BUCHI reserves the right to make changes to the manual as deemed necessary in the light of experi ence; especially in respect . Buchi Rotavapor R-100 Rotary Evaporators 11100C101 - Wolflabs 2 | Safety BCHI Labortechnik AG u Always wear appropriate personal protective equipment such as safety goggles, protective clothing and gloves. Operation Manual (Original) Rotavapor R-100 11593663 Publication date: 10.2019 BCHI Labortechnik AG Meierseggstrasse 40 Postfach CH-9230 Flawil 1 E-Mail: quality@buchi.com BUCHI reserves the right to make changes to the manual as deemed necessary in the light of experi-ence, especially with respect to structure, illustrations and technical . u Wear work overalls or protective clothing. To fasten condenser 032013 Cross sleeve. Thanks to smart system design and substantial reductions in organic solvent use, the Sepiatec SFC line enables a more efficient and eco-friendly purification performance. The F100 and F105 are sealedsystem recirculating chillers. (60 pages) Laboratory Equipment Buchi Rotavapor R-3000 Operating Instructions Manual. The products you use, the products you need, the suppliers you trust for chromatography. These operating instructions apply to all variants of the Rotavapor R100 and are in tended primarily for laboratory staff. The independent heating bath is controlled by an integrated digital display and can easily be operated separately for different applications. u Do not wear loose or baggy items of clothing such as scarves or neckties. Turn off the rotary drive unit (set the rotation speed to 0 rpm). any latin characters (a-z, A-Z) any numbers (0-9) special characters ("-", "_" and ". u Use only genuine BUCHI accessories, spare parts and consumables. Follow the links below for an up-to-date list of spare parts and service availability for legacy devices from BUCHI technical support. Insert seal (2) into the flange of the condenser (1) as shown. Rotavapor R-100. Shop By. u Always visually inspect glass components for damage every time they are to be used. There are four danger levels, each identifiable by the signal word used. Fisher Scientific is always working to improve our content for you. Using a narrow object or screwdriver, press the switch (1) on the underside of the heating bath. Rotavapor R-100 Rotary Evaporators Standalone, BUCHI, Life Science Research Solutions, Products, and Resources, Controlled Environment and Cleanroom Solutions, How to Select the Right Chromatography Resin, Thermo Scientific Chromatography Columns and Consumables, Liquid Chromatography - Sample Preparation, Biopharma production chemicals & excipients, Laboratory Personal Protection Equipment (PPE) and Workwear Products, Laboratory Facilities Maintenance, Protection, and Hygiene Supplies, Building a Safe Work Environment with VWR, New Solutions - Controlled Environment and Cleanroom Products, Solutions by Industry Controlled Environment and Cleanroom Product, Safety and Controlled Environment Featured Brands, Controlled Environment & Cleanroom Sustainable Solutions, Masterflex Peristaltic Pump and Fluid Handling Solutions, Quality Products from Sheldon Manufacturing, Lab Thermometers & Temperature Measurement Equipment, Agilent Chemistries and Supplies Portfolio, PerkinElmer - Innovating for a Healthier World, Sartorius laboratory instruments, consumables and services, HALO Chromatography Columns and Consumables+-, The Avantor Value as a Medical Lab Partner, Reference materials Laboratory Products, Specialized Solutions for Cutting Applications, Contact Your Laboratory Furniture Specialist. This manual is copyrighted. It has always been our goal at BUCHI to develop long-lasting and reliable instruments. 1 2 3 4 5 1 Vacuum connection seal 4 Feed tubing seal 2 Coolant seal 5 Vacuum gasket (not visible) 3 Coolant seal u Remove seals and inspect for damage and cracks. u If pure distilled or deionised water has to be used, add 1 to 2 g of Borax (Na2B4O7 x 10 H2O) per litre of water. Distillation can produce dangerous vapors that are capable of causing lifethreatening toxic effects. BCHI Labortechnik AG Help with faults | 8 Fault Possible cause Optimum distilla Too much backevaporation tion not from the receiving flask (espe achieved cially with solvent mixtures) Other faults in distillation process (e.g. The vapor duct snaps into place with an audible click. 5. Our global footprint enables us to serve more than 300,000 customer locations and gives us extensive access to research laboratories and scientists in more than 180 countries. Want your creations to burst with flavor? The R-300 meets the highest expectations in convenience and versatility. u Make sure that any dripping condensate cannot cause any damage. Restriction valve, hose clamp, sieve Used when tap water is applied as vacuum source, to reduce flowrate of the water 011606 Water jet pump. The compact system can be operated anywhere by anyone thanks to a simple interface and pre-calibration packages that ensure speed and quality. BUCHI reserves the right to make changes to the manual as deemed necessary in the light of experi ence; especially in . Quick and ergonomic operation with smooth manual lift mechanism; Easy flask handling and vapor duct removal due to multifunctional Combi-Clip; u Switch off the device. Couppling, pressure spring 048237 Rubber band. As our customers needs have evolved, so have our capabilities. High-quality chemicals and services, customized to your product or manufacturing needs VWR enables the advancement of science by providing high-quality chemicals and services, customized to your product or manufacturing needs. particularly suitable for the Rotavapor R-100. The Rotavapor R-100 is an effective rotary evaporator for limited budgets. (60 pages) Laboratory Equipment Buchi Rotavapor R-100 Operation Manual. If vapors escape from joints or connections, check the seals concerned and re place them if necessary. 100mL flask (5pcs) 001333 Glass, SJ29/32, incl. 50mL flask (5pcs) 011574 Glass, SJ29/32, incl. The glass stopcock performs various functions depending on its position: Glass stopcock handle pointing forwards or backwards: the system is sealed. New Avantor J.T.Baker premium conductive and non-conductive robotic tips deliver superior quality and reliable performance for results you can trust. to BUCHI products Status Color explanation Spare parts and service available . Add to Wish List Add to Compare. "), Operation Manual (Original) Rotavapor R100 11593663 en. Its modular design allows extension of the Rotavapor R-300 to a fully integrated system where a central interface regulates each component. Don't miss out, order yours today! 5 | Installation BCHI Labortechnik AG 5.8 Setting up and filling the heating bath 1 2 u Locate the heating bath (1) in the Lshaped cutout in the Rotavapor base (2). Buchi Rotavapor R-100 Operation Manual (60 pages) Brand: Buchi | Category: Laboratory Equipment | Size: 4.35 MB Table of Contents. 2.6 Modifications Unauthorized modifications may impair safety and lead to accidents. u If a vacuum pump is not used, leave the vacuum connection open. 10 | Appendix BCHI Labortechnik AG Cap nuts, set. Rotary evaporator Buchi Rotavapor R-100 system vertical condenser, for use under vacuum, manual flask lift, safety coating on glassware, F-105 chiller included, V-100 pump and I-100 pump controller included, B-100 bath included Power Draw: 2.74kW: Ecological Features: In continuous uncontrolled operations, drops power consumption automatically.

Ibanez Steve Vai Signature Jem Series, Georgia State University Grades, Bosch Gws10 8 76v Ec Professional Compact Angle Grinders, Voigtlander Bessa Eyepiece, Articles B

buchi rotavapor r-100 manual